Check appliances, add the surge, and size the generator before you buy.
⚡ Size to starting watts: motors briefly draw 2-3× their running watts. Start the biggest motor first, then the rest. Inverter generators are safe for electronics; 240 V well pumps and AC compressors need a transfer switch and an electrician.
The Generator Wattage Calculator is based on the following formula:
Running load = Σ(Running watts × Qty) Surge = Running load + max[(Surge watts − Running watts) × Qty] Recommended = smallest standard size ≥ Surge Standard sizes = 2,000 / 3,000 / 4,000 / 5,000 / 6,500 / 7,500 / 10,000 / 12,000 / 15,000 / 18,000 / 22,000 / 24,000 W
Variables: Running watts = Steady-state draw of each appliance Surge watts = Brief starting draw (motors: 2-3× running) Qty = Number of that appliance running simultaneously max(...) = The largest single motor bank assumed to start while everything else runs (start big motors first)
Generators carry two ratings: continuous running watts and a surge rating they hold for seconds. Because you can sequence motor starts, sizing adds only the largest surge margin on top of the combined running load, then snaps up to the next standard model class.
Worked example: Step 1: Selected — refrigerator 700/2,200 W, furnace blower 800/2,350 W, LED lights 100/100 W, microwave 1,000/1,000 W. Step 2: Running = 700 + 800 + 100 + 1,000 = 2,600 W. Step 3: Surge margins: 1,500 / 1,550 / 0 / 0 → largest is 1,550 W. Step 4: Surge = 2,600 + 1,550 = 4,150 W. Step 5: Smallest standard ≥ 4,150 is 5,000 W. Result: a 5,000 W class generator — the tool's Load Sample produces these exact numbers.
Anything with a motor — refrigerator compressor, furnace blower, well pump, AC — briefly pulls 2-3× its nameplate running watts to overcome inertia. Generator spec sheets list both a running (rated) wattage and a higher surge wattage the machine tolerates for a few seconds. Size the generator to the surge number, not the running one.
Add the running watts of everything that will run simultaneously. Then add the largest single surge margin on top, because you can sequence your starts: fire up the well pump first, and once it is running, switch on the fridge. That is exactly the method this tool uses — and why starting order is the cheapest capacity upgrade you own.
Generators come in steps: roughly 2,000 W inverters for tailgates, 3,000-5,000 W for fridge-and-furnace basics, 7,500-12,000 W with 240 V for well pumps and AC, and 15-24 kW standby units that back up a whole panel. The tool snaps your surge total up to the next standard class so you can shop a real model number.
Heating elements — space heaters, hair dryers, kettles, water heater elements — have no surge at all but devour continuous watts. An electric water heater alone claims 4,000 W for hours. During an outage, prioritize refrigeration, heat, sump pumps, and lighting; leave resistive gluttons on the grid.